biosep-chiarificatori-2

For the final treatment of domestic sewage of small residential agglomeration, where they are present traditional systems of septic tanks or septic type.

Monobloc prefabricated tanks made of reinforced fiberglass.

Dimensioned according to the activated sludge system for total oxidation.

For domestic sewage from 6 to 50 inhabitants.

APPLICATIONS

For all dwellings or activities that are not connected to the sewerage system and where there are primary treatment systems such as septic tanks or septic; our facilities “BIOSEP”; complete biological purification cycle.

CONNECTION SYSTEM

biosep-chiarificatori-1

The wide range available Allows you to choose the most appropriate model for your needs, it is essential to follow the indacazioni local authorities competententi about the permits for the dumping, to which the legislative decree.152 of 11/05/99 see the definition of discharges treatments.

10 YEARS GUARANTEE

– Lower weight and therefore easy handling.
– Resistant against aggressive substances and therefore leakproof.
– Greater stability of the structure of the external counterforce to the ground.

TREATEMENT’S DESCRIPTION

The sewage was coming out of the traditional need to improve their level of purification with our systems of Biosep series completes the biological purification cycle. Through the Biosep system, to attivti sludge for total oxidation favors the development of aerobic bacteria that degrade the organic substance, giving rise to completely mineralized sludge, the dimensioning of these systems allows the slurry a residence time sufficient for there to be complete oxidation of the organic substance. In this series of plants are distinguished two compartments: the first oxidation and the second decantation. They are supplied pre-assembled in their internal components, such as input-output-vent fittings, air diffusers, recycling sludge and foams, the kit is completed by the pump (oxygenator) from the control cabinet, the connecting fittings and products for aN effective goodwill.

 

TECHNICAL DATA

TECHNICAL PLAN

biosep-chiarificatori-2

PROJECT’S PARAMETERS

DEPURATION’S EFFICIENCY

The plants take in operating regime and respecting the design values ​​is able to make a tributary correspond to what is required by the tab. 3 all. 5 DL 157/99. The yield purifying warranties are effective only if the maintenance and management is done properly.